Search results for "optical [potential]"
showing 10 items of 5737 documents
Autofluorescence imaging for recurrence detection in skin cancer postoperative scars
2020
This clinical study is a first attempt to use autofluorescence for recurrence diagnosis of skin cancer in postoperative scars. The proposed diagnostic parameter is based on a reduction in scar autofluorescence, evaluated in the green spectral channel. The validity of the method has been tested on 110 postoperative scars from 56 patients suspected of non-melanoma skin cancer, with eight patients (13 scars) available for the repeated examination. The recurrence diagnosis within a scar has been made after two subsequent autofluorescence check-ups, representing the temporal difference between the scar autofluorescence amplitudes as a vector. The recognition of recurrence has been discussed to r…
Electrochemical detection and screening of bladder cancer recurrence using direct electrochemical analysis of urine: A non-invasive tool for diagnosis
2018
Although detection of urothelial cell carcinoma (or bladder cancer, BC) can be performed via cytological, molecular and genetic marker tests on urine, cystoscopy, an invasive technique, still remains as the gold methodology in clinical practice. It is presented a non-invasive method for detecting BC recurrence consisting of a direct electrochemical test in urine combining voltammetric data at gold and glassy carbon electrodes. The diagnosis is based on the ratio between characteristic voltammetric features recorded for tryptophan, serotonin and melatonin and other related metabolites. The method was tested by means of a clinical trial with 30 patients diagnosed of bladder cancer and a two c…
Effect of training level and blood flow restriction on thermal parameters: Preliminary study
2016
Abstract Training with blood flow restriction could lead to an effect on skin temperature. Additionally, this effect could be higher in people with lower physical fitness level due to their lower capacity of heat loss. The aim of this preliminary study was therefore to evaluate the effects of training experience on the acute and chronic thermal skin responses after performing exercise with and without blood flow restriction. The study included ten men, of these, five were trained. All subjects performed tests and re-tests for maximum strength (1 repetition maximum) through unilateral leg extensions (right thigh at 45 ± 6.7 kg and left thigh at 45.5 ± 8.1 kg, p > 0.05). The protocol consiste…
Postoperative Lens Position Preoperatively Determined by Scheimpflug Photography
1999
The position of the artificial lens has an important influence on refractive power calculation. We compared the position of the crystalline lens with that of the artificial lens after cataract surgery by means of Scheimpflug photography. A difference in position of approximately 0.8 mm in the anterior direction could be determined.
Perfluoroalkylated amphiphilic MUC1 glycopeptide antigens as tools for cancer immunotherapy.
2010
The synthesis of perfluoroalkylated glycopeptide antigens and their specific binding to anti-MUC1 mouse antibodies is reported.
Melting point, molecular symmetry and aggregation of tetrachlorobenzene isomers: the role of halogen bonding
2018
Tetrachlorobenzenes represent one of the best known, but not yet fully understood, group of isomers of the structure–melting point relationship. The differences in melting temperatures of these structurally related compounds were rationalized in terms of the hierarchy and nature of formed noncovalent interactions, and the molecular aggregation that is influenced by molecular symmetry. The highest melting point is associated with the highly symmetric 1,2,4,5-tetrachlorobenzene isomer. The structures of less symmetrical 1,2,3,4-tetrachlorobenzene and 1,2,3,5-tetrachlorobenzene, determined at 270 and 90 K, show a distinct pattern of halogen bonds, characterized by the different numbers and typ…
Decomposition Process of Carboxylate MOF HKUST-1 Unveiled at the Atomic Scale Level
2016
HKUST-1 is a metal-organic framework (MOF) which plays a significant role both in applicative and basic fields of research, thanks to its outstanding properties of adsorption and catalysis but also because it is a reference material for the study of many general properties of MOFs. Its metallic group comprises a pair of Cu2+ ions chelated by four carboxylate bridges, forming a structure known as paddle-wheel unit, which is the heart of the material. However, previous studies have well established that the paddle-wheel is incline to hydrolysis. In fact, the prolonged exposure of the material to moisture promotes the hydrolysis of Cu-O bonds in the paddle-wheels, so breaking the crystalline n…
Fundamental limits for transmission modulation in VO2 metasurfaces
2022
The interest in dynamic modulation of light by ultra-thin materials exhibiting insulator–metal phase transition, such as VO 2 , has rapidly grown due to the myriad industrial applications, including smart windows and optical limiters. However, for applications in the telecommunication spectral band, the light modulation through a thin VO 2 film is low due to the presence of strong material loss. Here, we demonstrate tailored nanostructuring of VO 2 to dramatically enhance its transmission modulation, reaching a value as high as 0.73, which is 2 times larger than the previous modulation achieved. The resulting designs, including free-topology optimization, demonstrate the fundamental limit i…
Excitation Transfer Engineering in Ce-Doped Oxide Crystalline Scintillators by Codoping with Alkali-Earth Ions
2018
This work has been supported by the European Social Fund Measure No. 09.3.3-LMT-K-712 activity Improvement of Researchers Qualification by Implementing the World-Class R&D Projects, and by grant #14.W03.31.0004 of the Russian Federation Government. Authors are grateful to CERN Crystal Clear Collaboration and COST Action TD1401 "Fast Advanced Scintillator Timing (FAST)" for support of collaboration.
Chromogenic detection of nerve agent mimics
2008
The current rise in international concern over criminal terrorist attacks via chemical warfare (CW) agents has resulted in an increasing interest in the detection of these lethal chemicals. Among CW species, nerve agents are extremely dangerous and their high toxicity and ease of production underscore the need to detect these deadly chemicals via quick and reliable procedures. A number of detection systems have been developed, most of them based on enzymatic and physical methodologies. However, these usually show limitations such as low selectivity, lack of portability and a certain complexity in their use. An alternative to these classical methods that has been gaining interest in recent y…